Enlarge image
Image 1 of 6
Model: ST-T103
ST-T103 Crack-Resistant Stain-Resistant Elastic Building Coating for Exterior Wall
ST-T103 acrylic exterior wall coating for wall substrates. Intended for outdoor use. Supplied in liquid form.
Reference price (FOB)
US $2.3-2.5 / kg
Minimum order: 100 kg
Confirm the specification, quantity and shipping terms for your quotation.
Request a QuoteProduct specifications
- Model NO.
- ST-T103
- Color
- Customize
- Appearance
- Liquid
- Main Raw Material
- Acrylic
- Method
- Spray
- Level
- Finish Coat
- Drying Method
- Air Drying
- Substrate
- Wall
- Components
- Film Forming Matter
- Formation Mechanism
- Conversion Type
- Film-Forming Substance
- Premium Elastic Acrylic Emulsion
- Performance
- Elasticity and Stain Resistance
- Theoretical Coverage Rate
- 0.25-0.3 Kg/M²
- Surface Drying Time
- ≤ 2h (at 25°c, Rh≤ 85%)
- Recoating Interval
- ≥ 4h(at 25°c, Rh≤ 85%)
- Trademark
- SINGAL
- Transport Package
- Barrel Package in Pallet
- Specification
- 20kg/Barrel
- Origin
- China
- HS Code
- 32091000
- Customization
- Available
- Production Capacity
- 50000ton/Year
- Package Size
- 30.00cm * 30.00cm * 35.00cm
- Package Gross Weight
- 20.000kg
- Main Components
- Elastic acrylic emulsion, pigments and fillers, various additives
- Theoretical coating rate
- 0.25-0.3kg/m² (2 times, the actual coating rate of the product will vary depending on different factors)
- Surface drying time
- ≤2h(25°C, RH≤85%)
- Recoat interval
- ≥4h (25°C, RH ≤85%)
Packaging & shipping
- Transport Package
- Barrel Package in Pallet
- Specification
- 20kg/Barrel
- Package Size
- 30.00cm * 30.00cm * 35.00cm
- Package Gross Weight
- 20.000kg
Product description
Premium Crack-resistant Stain-resistant Elastic Building Coating for Exterior Wall
The product is primarily formulated with high-quality elastic acrylic emulsion as its key film-forming substance, complemented by imported pigments, fillers, and additives. It is meticulously crafted through an automated production line, delivering exceptional elasticity and stain resistance while ensuring superior crack resistance performance.
Quality management system
Specifications
Applications:
It is suitable for both new construction and renovation projects of various indoor and outdoor buildings, including residential properties, office buildings, hotels, factories, schools, and more.
Performance characteristics:
Performancfe Parameters
| Main Components | Elastic acrylic emulsion, pigments and fillers, various additives |
| Color | Customize |
| Theoretical coating rate | 0.25-0.3kg/m² (2 times, the actual coating rate of the product will vary depending on different factors) |
| Surface drying time | ≤2h(25°C, RH≤85%) |
| Recoat interval | ≥4h (25°C, RH ≤85%) |
1. Primer Layer: Singal Alkali-Resistant Sealing Primer.
3. Topcoat: Singal Elastic Coating.
Construction Guidance:
2.Application Methods: Suitable for spraying, rolling, or brushing.
3.Dilution: Adjust based on actual construction conditions, using no more than 10% clean water for dilution.
4.Construction Conditions: Temperature range: 5-40°C; relative humidity ≤85%. Avoid application during windy/rainy seasons or extreme heat.
5.Cleanup: Rinse tools thoroughly with clean water immediately after use.
Construction Instructions
1. Base Layer Instructions
1.1 Before base layer treatment, the wall needs a certain curing period. Generally, new cement walls require 28 days of curing in winter and 14 days in summer.
1.2 Before applying putty, thoroughly remove loose, peeling, hollow, or powdery base layers, then eliminate dirt such as dust and oil.
1.3 After the first full putty application, use a trowel to smooth it. After slightly drying (generally 3-4 hours), apply the second layer of putty. Once the putty is dry, sand it carefully with sandpaper to remove trowel marks and joints.
1.4 The flatness of the putty surface should be ≤1.5mm.
2. Construction Specifications
2.1 Stir well before construction.
2.2 Roller coating: Dip a roller into the diluted Shengong elastic paint container, roll it on a construction tray to evenly distribute the paint on the roller surface, then apply it to the wall.
2.3 Spray painting: Ensure consistent product dilution ratio, air pressure, spray gun nozzle size, and spraying distance.
3. Precautions
3.1 Read the construction instructions carefully before starting.
3.2 Do not construct when the temperature is below 5ºC, wind force exceeds grade 4, or in rain, snow, or when the wall temperature exceeds 50ºC.
3.3 Store in a cool, clean, dry place at 0-35ºC. Use the product promptly after opening. (Note: Product performance and construction parameters are obtained under laboratory conditions, but actual usage conditions vary. The company reserves the right to revise the product instructions without prior notice.)
Construction Methods and Procedures
| Work procedure | Material | Consumption Rate (kg/m²) | Recoat Time (at 20°C), h |
Number of Coats | Construction Process |
| Primer Layer | Alkali-Resistant Sealing Primer | 0.1-0.15 | 8-12 | 1 | Roller,Spray |
| Putty layer | Two-Component Elastic Putty | 1-1.5 | 8-12 | 1-2 | Scrape |
| Topcoat Layer | Elastic Coating | 0.25-0.3 | 8-12 | 2 | Roller,Spray |
Discuss this product for your project