Model: NH

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures

NH non-intumescent fireproof coating. Intended for indoor use.

Reference price (FOB)

US $1-1.5 / kg

Minimum order: 100 kg

Confirm the specification, quantity and shipping terms for your quotation.

Request a Quote

Product specifications

Model NO.
NH
Fire Prevention Mechanism
Non-Expansion Steel Structure
Thickness
Thick
Use
Fireproof Coatings For Steel Structures
Shelf Life
9 Months
Type
Fireproof Coating
Model
Nh
Mixing Ratio of The Interfacial Layer Co
Powder Material : Water : Binder = 100:120:40
Specification
20kg
Trademark
Singal
Origin
China, Shandong
HS Code
3208909090
Production Capacity
50000ton/Year
Package Size
80.00cm * 50.00cm * 10.00cm
Package Gross Weight
20.000kg

Packaging & shipping

Specification
20kg
Package Size
80.00cm * 50.00cm * 10.00cm
Package Gross Weight
20.000kg

Product description

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel StructuresEco-friendly Non-toxic  Indoor Thick Non-intumescent Fire-resistive Fireproof Coating for Steel Structures

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures
NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures

This product is a composite material formulated with lightweight thermal insulation components and inorganic hydraulic binders. When applied to indoor steel structures, it forms a fire-resistant and thermal-insulating protective layer that prevents damage to load-bearing steel members during fire incidents. The coating demonstrates excellent adhesion, flexibility, and crack resistance properties.&

 

Product  Features

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures

 

Application Area

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures
Suitable for fire protection of large-scale indoor steel structures in warehouses, stadiums, exhibition centers, office buildings, train stations, and similar facilities.

 

Featured projects

NH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel StructuresNH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel StructuresNH Low Voc Indoor Thick Non-Intumescent Fire Retardant Fireproof Coating for Steel Structures

 

Construction Technology

   1.    The steel structure substrate must be decontaminated and rust - proofed, and generally at least two coats of high - quality anti - rust primer should be applied.

  2.    After the primer is completely dry, the dust and dirt on the surface of the anti - rust paint must be removed before applying the steel structure fire - retardant coating.

  3.    Before using the product, it must be thoroughly mixed according to the specified mixing ratio. The application is generally carried out by spraying or troweling; it is recommended to use specialized heated two-component spraying equipment for construction.
  4.    When using airless spraying equipment, carefully control the application viscosity and the thickness of each coat. A small amount of thinner can be used for dilution, but the amount should be controlled within 10% of the coating volume. The prepared product must be used up within 2 hours; materials left unused for more than 2 hours should not be used further.
  5.     Construction Mixing Ratio: Component A : Component B = 2.5:1
  6.     Construction should be carried out following the principles of top-to-bottom, left-to-right, inside-to-outside, difficult-to-easy, and crisscross patterns.
  7.     Determine the coating thickness and number of coats based on the fire resistance rating standards specified by the design and fire department.
   8. When the coating thickness exceeds 6mm, it is recommended to reinforce with fiberglass mesh.
   9.      The construction temperature for this product should be controlled between 5ºC and 38ºC, with humidity not exceeding 85%. Construction should not be carried out in rainy, snowy, foggy, windy weather, or when there is condensation on the steel surface.
   10.     The interval between successive coats should be controlled at approximately 24 hours and should not be excessively long.

 

Notes
      1.    If airless spraying is adopted, a special sprayer must be used. Avoid excessive dilution of the coating, as this will affect the adhesion of the product. Construction is not suitable when the wind force exceeds level 5.

    2.

    3.    Store in an environment of 0-38ºC, keep away from fire sources and heat sources, and prevent exposure to sunlight.

    4.    The storage period is 12 months.

 